Thanks for purchasing YINGTAI centrifuge

For the fast and fine service,
Please peruse the product specification before operation

Our motto:

Serve you is our duty

Satisfy you is our goal

CUSTOMER FIRST

 QUALITY IS OUR FOUNDATION

CHANGSHA YINGTAI INSTRUMENT CO., LTD

Warning

Thanks for using our centrifuge, make sure you have read the following items before operating, in case of operation accident.

  1. Please dismantle the power plug, when the machine is in maintenance or it won’t be used for a long time, or it still has electricity.
  1. Unbalance operation and tube with large weighing mistakes after the liquid input are all forbidden
  1. Operation over the max speed is forbidden in case of disaster accident.
  1. The rotor with crackle is forbidden, or explosion will be happened.

Your cooperation is appreciated

                   Changsha YINGTAI instrument CO., LTD

Ⅰ、model name
 Table top low speed urine sediment centrifuge TD4N
Ⅱ、Function and scope of use
    TD4NTable top low speed urine sediment centrifuge is an ordinary instrument used in the field of medicine and biology.
Ⅲ、Technical parameter 

items

technical parameter

max speed

4000 r/min

max capacity

8×15ml

Max RCF

2600×g

Time range

0-99min

noise

65dBA

power

220V  50Hz   5A

Outer dimension

370mm×513mm×270mm

Ⅳ、available rotor

Rotor NO.

Rotor name

Capacity
quantity of tube*ml

Max speed
r/min

Max centrifugal radiusmm

Max RCF*g

31601

swing rotor

8×15

4000

145

2600

31602

swing rotor

6×15

4000

140

2500

Ⅴ、Working theory
    With the direct current brushless motor drive, speed and time digital display, it is in simple construction, it is reliable and convenient in operation, make sure centrifugal tubes are in the same level in your eyes before centrifugation. It is Unnecessary to weigh the liquid. The reliable electrical lock assures you safe operation.
Ⅵ、open the package
You should check whether the package is in good condition when you receive the product, if so, open the package, take out the operation manual, check the body and accessories according to the manual, make sure they are in full set, if you found some damages happened to the machine or something missing, please contact us directly.
Ⅶ、fix
Put the centrifuge on the working table, make sure it is stable, let the four rubber pads on the bottom of the machine touch the table completely, and then insert the plug into the socket, one socket is on the right bottom of the centrifuge, the other socket is the power socket. Make sure the power socket connect with the earth, in case of accident.
Ⅷ、operation
1 See whether the circular nut is loose, if so, tighten it, and then put the rubber pad into the centrifugal tube frame.
  2 Add sample liquids into the tubes, figure they are on the same level.
  3 Put the centrifugal tubes into the rotor, the tubes must be even in the quantity. Or the machine will vibrate severely, because of imbalance.
  4 Close the cover, make sure it is locked.
  5 set parameters
Speed and time are all showing on the window of the machine, switches and press button as the following diagram.                                                                                                                                          

  1set speed
     Press button “speed up”the speed will up from 0r/min to 4000r/min,
Press button “speed down”the speed will down, set the speed you want , after finished, the digital tube will flashes 3 times, the speed you set will be memorized automatically.
  2set time
      Press button “time up”  the time will up from 0 minute to 99minute
 Press button “time down” the time will down, set the time you want, after finished, the digital tube will flashes 3 times, the time you set will be memorized automatically.
7 START
   Press button “start” “starting lamp” will be oncentrifuge starts to work “speed showing window” will show the speed, “time showing window” will show the countdown timeit will up to the speed you set in 2 minutes , when the centrifuge is in operation, press the button “relative centrifugal force” the relative centrifugal force will be showing transferable, 10 minutes later ,it will show the speed again.
8 STOP
     When the countdown time till 0 press button “stop”, the stop lamp will be on, the speed will decelerate, when the speed is 0r/min, The buzzer will sounds 6 times; it means the centrifuge has stopped.
9 Open the cover
Press the button “open”, the lock is unlocked with a bang, push the cover, the air spring will help you open the cover, take out the centrifugal tubes, finish centrifugalize. For your safe considering, in the process of centrifugation, even you press the button “open”, the cover won’t open, only when the speed is 0, and the buzzer sounds six times, you press the button “open”, the cover will open.
10 SHUT DOWN
     When centrifugalize finished, press the button ” stop”, if the machine will be in leisure for a long time, you should take out the plug, let the machine cut out.
  SAFE PROTECTION
   1 over speed protection
   For safe operating, when the actual speed is 500r/min faster than the max speed, the centrifuge will stop automatically. speed showing window will show E-3.
   2imbalance protection
   In the process of centrifugalize, The liquids in the tubes are in severely different level will result imbalance, when the vibration is over the preset standard, the centrifuge will stop automatically.” speed showing window” will show E-2.
   3opened cover protection
   When the cover or the lock isn’t locked well, press the button” start”, the centrifuge won’t work, the” speed showing window” show E-1
   4protecting the liquid when the centrifuge is off electricity
   When the centrifuge is off electricity for unforeseen reason, the centrifuge stopped, the button ”open the cover” won’t work, for protecting the fluid, the centrifuge with a bottom-ring, pull the bottom-ring, the lock and the cover will open automatically, then you can take the tubes out.
   5For protecting the worker, in the process of the centrifuge operation, open the cover is forbidden, when the speed is over 100r/min, the cover will be off electricity automatically, even the worker press the “open the cover” button by mistake, it won’t open. But the following operation is forbidden:
1When the speed is over 100r/min, you are forbidden to pull the bottom-ring, or accident will be happened
2You are forbidden to cut out the electricity and then plug in again artificially, the centrifuge will regards the speed is 0r/min, so the cover can be opened, the accident will be happened.
6Refresh the centrifugal tubes, you are forbidden to use the broken tubes.
7The cover of the tube has the function of preventing the splashing and overflowing of the liquids. In centrifugalize the poisonous masses, you can’t only depend on the cover of the tube, in opening the cover of the machine or cleaning the centrifugal cavity, you must care for the overflowed poisonous.
8When some damages happened to the rotor, you can only move the centrifuge 30cm, make sure there are no dangerous items around the centrifuge within 30cm.
9The worker is forbidden to lean on the centrifuge, when it is in operation.
10When some thing wrong happens to the centrifuge, the non-professional technician is forbidden to repair it. You can ask the professional technician to repair it or send it back to us for repairing. In the process of repairing, the centrifuge must be cut out; you should take out the plug from the power socket. Or accident will be happened.
troubleshooting
     Press the button “start”, if the “starting lamp” won’t light, first you should check the socket in the right bottom of the machine, see whether the socket has fused, if so, replacing it with a 5A fuse. If not, second you should remove the screw right down the front board, take out the front board, checking whether the pin in the switch is loose. If so, you should tighten the pin. Third maybe the switch is broken, if so, you can replace it. If the machine doesn’t have the above mentioned problems, you can not repair it, you can contact us for help.
                      

TD4N
Table top low speed urine sediment centrifuge

 Certification

NO.              

The product is qualified after our testing

Shipping seal                        testing seal 

Changsha YINGTAI instrument co., ltd
August 1, 2007

Table top low speed urine sediment centrifuge TD4N

             SHIPPING LIST

NO.

NAME

QUANTITY

MARK

1

CentrifugeTD4N

1

 

2

    Operating manual

1

 

3

Power wire

1

 

4

wrench

1

 

5

rotor

1

 

                          Changsha YINGTAI instrument co., ltd
 
August 10, 2007

dowload

 
   
Copy rights: Changsha YINGTAI instrument co.,ltd
Add:105# building22,districtC,WNAGHCENPO economic development zone ,changsha ,hunan
Hotline:0731-8817783 / 2843888   Fax:0731-8112246 E-Mail:centrifuge@cn-centrifuge.com
Our company has auquired the ISO9001:2000 certification (file NO. MSF11-18)
PRC Ministry of Information Industry: